Ubbelohde viscosity meter1/29/2024 ![]() ![]() Calibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140☏ Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. by measuring a reference liquid of known viscosity. Cannon-Ubbelohde, CUU And CUC Series Viscometers. This constant needs to be determined for each capillary by calibrating the capillary, i.e. Rotating bobs are more common, rotating cups reduce the likelihood of vortex formation, and "cone and plate" viscometers create a constant shear rate at any speed. To obtain kinematic viscosity (v ny), multiply the measured flow time (t f) by the so-called capillary constant (K C ). ![]() Rotational viscometers use the concept of torque to measure the effort required to turn a disk or bob in a fluid. Many capillary-tube viscosimeters have been devised, but Ostwald and Ubbelohde viscosimeters are among the most frequently used. In tribology and the study of lubrication, viscosity. Let's discuss the various styles of viscometers, their internal characteristics and factors that go into performing a precise and repeatable viscosity measurement. This can be done electronically for opaque fluids. Measurement of Viscosity The usual method for measurement of viscosity involves the determination of the time required for a given volume of liquid to flow through a capillary. A viscometer is an instrument used to measure fluid viscosity and the flow properties of liquids. You calculate viscosity by measuring the amount of time it takes for the liquid to move between two marks.įalling ball viscometers measure the time it takes for a sphere of a known size and density to descend through a stationary liquid. Liquid is drawn by suction into the upper bulb and allowed to flow down into the lower bulb. Glass capillary viscometers or Ostwald or Ubbelohde viscometers consist of a U-shaped glass tube held vertically in a controlled temperature bath. This item: 1835 Ubbelohde Viscometer Glass Capillary Viscosity Meter (0.3-0.4mm) 99.00 99. What Are the Different Types of Viscometers? Viscometers measure using a single flow condition. By adjusting the dimensions of the apparatus with extreme precision Ubbelohde explicitly recommended commercial manufacture the absolute viscosity could be calculated simply by multiplying or dividing the time by a power of 10. In general, viscometers move an object through a stationary fluid or move the fluid past a stationary object to measure the friction between the fluid and the object or surface. The time taken for the liquid to travel between the marks M and M1 was then recorded. ![]()
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |